ȸ»ç¼Ò°³ | ÀÚ·á½Ç | °Ô½ÃÆÇ | ȸ¿ø¼­ºñ½º |   

 
 
 
 
 
 
 
home > VuPower
 


 

 

    •     Bench-top and 19-inch standard rack mountable
    •     Self-compensation by monitoring output and display
    •     CV/CC mode automatic crossover by setup limit
    •     RS-232 & GPIB(IEEE488.2) interface
    •     Storable up to 10 settings at each output port
    •     Pattern output operation
    •     Power fail feature to recall the latest setting value
    •     DUT protection by OVP & OCP
    •     Rear output enable

Model

K1810

K3010

K3003

K3005

K6003

Max. Ouput power

180W

300W

90W

150W

180W

DC Output

Voltage

18V

30V

30V

30V

60V

Current

10A

10A

3A

5A

3A

Programming Accuracy     ±(% of output + offset)

Voltage

0.05%+15mV

0.05%+15mV

0.03%+15mV

0.03%+15mV

0.05%+20mV

Current

0.1%+10mA

0.1%+10mA

0.1%+5mA

0.1%+5mA

0.1%+5mA

Readback Accuracy     ±(% of output + offset)

Voltage

0.05%+12mV

0.05%+12mV

0.03%+10mV

0.03%+10mV

0.05%+15mV

Current

0.1%+7mA

0.1%+7mA

0.1%+3mA

0.1%+3mA

0.1%+3mA

Load Regulation     ±(% of output + offset)

Voltage

0.01%+2mV

0.01%+3mV

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

0.01%+1mA

0.02%+1mA

Line Regulation   ±(% of output + offset)

Voltage

0.01%+2mV

0.01%+3mV

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

0.01%+1mA

0.01%+1mA

Ripple & Noise   (20Hz to 20MHz)

Normal Mode Voltage

0.5mVrms, 4mVpp

0.5mVrms, 5mVpp

0.5mVrms, 3mVpp

0.5mVrms, 3mVpp

0.5mVrms, 4mVpp

Normal Mode Current

2mArms

2mArms

1mArms

1mArms

1mArms

Resolution

Program

1mV/1mA

1mV/1mA

1mV/1mA

1mV/1mA

10mV/1mA

Readback

1mV/1mA

1mV/1mA

1mV/1mA

1mV/1mA

10mV/1mA

Meter

1mV/1mA

1mV/1mA

1mV/1mA

1mV/1mA

10mV/1mA

Voltage Programming Speed

Up - Full Load
      No Load

10msec
10msec

12msec
12msec

12msec
12msec

12msec
12msec

16msec
16msec

Down - Full Load
          No Load

13msec
100msec

15msec
110msec

15msec
110msec

15msec
110msec

20msec
250msec

Transient Response

Less than 50us for output recover to within 15mV following a change in current output from full load to half load

Command Processing Time

50msec < 100msec

»çÀ̹ö°ßÀû´ã±â

K1810

K3010

K3003

K3005

K6003



    •     Bench-top and 19-inch standard rack mountable
    •     Self-compensation by monitoring output and display
    •     CV/CC mode automatic crossover by setup limit
    •     Storable up to 10 settings at each output port
    •     Power fail feature to recall the latest setting value
    •     DUT protection by OVP & OCP
    •     Rear output enable

Model

AK3010

AK3003

AK3005

AK6003

Max. Ouput power

300W

90W

150W

180W

DC Output

Voltage

30V

30V

30V

60V

Current

10A

3A

5A

3A

Programming Accuracy     ±(% of output + offset)

Voltage

0.05%+15mV

0.03%+15mV

0.03%+15mV

0.05%+20mV

Current

0.1%+10mA

0.1%+5mA

0.1%+5mA

0.1%+5mA

Readback Accuracy     ±(% of output + offset)

Voltage

0.05%+12mV

0.03%+10mV

0.03%+10mV

0.05%+15mV

Current

0.1%+7mA

0.1%+3mA

0.1%+3mA

0.1%+3mA

Load Regulation     ±(% of output + offset)

Voltage

0.01%+3mV

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

0.02%+1mA

Line Regulation   ±(% of output + offset)

Voltage

0.01%+3mV

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

0.01%+1mA

Ripple & Noise   (20Hz to 20MHz)

Normal Mode Voltage

0.5mVrms, 5mVpp

0.5mVrms, 3mVpp

0.5mVrms, 3mVpp

0.5mVrms, 4mVpp

Normal Mode Current

2mArms

1mArms

1mArms

1mArms

Resolution

Program

1mV/1mA

1mV/1mA

1mV/1mA

10mV/1mA

Meter

1mV/1mA

1mV/1mA

1mV/1mA

10mV/1mA

Voltage Programming Speed

Up - Full Load
      No Load

12msec
12msec

12msec
12msec

12msec
12msec

16msec
16msec

Down - Full Load
          No Load

15msec
110msec

15msec
110msec

15msec
110msec

20msec
250msec

Transient Response

Less than 50us for output recover to within 15mV following a change in current output from full load to half load

»çÀ̹ö°ßÀû´ã±â

AK3010

AK3003

AK3005

AK6003



    •     Bench-top and 19-inch standard rack mountable
    •     Self-compensation by monitoring output and display
    •     CV/CC mode automatic crossover by setup limit
    •     RS-232 & GPIB(IEEE488.2) interface
    •     Storable up to 10 settings at each output port
    •     Pattern output operation
    •     Power fail feature to recall the latest setting value
    •     DUT protection by OVP & OCP
    •     Rear output enable
    •     Track function which interlocks P2

Model

K3003D

K3005D

K6003D

Max. Ouput power

90W x 2 / 180W

150W x 2 / 300W

180W x 2 / 360W

DC Output

Voltage

30V x 2

30V x 2

60V x 2

Current

3A x 2

5A x 2

3A x 2

Programming Accuracy     ±(% of output + offset)

Voltage

P1 : 0.03%+15mV
P2 : 0.10%+25mV

P1 : 0.03%+15mV
P2 : 0.10%+25mV

P1 : 0.05%+20mV
P2 : 0.10%+25mV

Current

P1 : 0.1%+5mV
P2 : 0.1%+10mV

P1 : 0.1%+5mV
P2 : 0.1%+10mV

P1 : 0.1%+5mV
P2 : 0.1%+10mV

Readback Accuracy     ±(% of output + offset)

Voltage

P1 : 0.03%+10mV
P2 : 0.10%+20mV

P1 : 0.03%+10mV
P2 : 0.10%+20mV

P1 : 0.05%+15mV
P2 : 0.10%+20mV

Current

P1 : 0.1%+3mV
P2 : 0.1%+7mV

P1 : 0.1%+3mV
P2 : 0.1%+7mV

P1 : 0.1%+3mV
P2 : 0.1%+7mV

Load Regulation     ±(% of output + offset)

Voltage

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

Line Regulation   ±(% of output + offset)

Voltage

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

Ripple & Noise   (20Hz to 20MHz)

Normal Mode Voltage

P1 : 0.5mVrms, 3mVpp
P2 : 0.5mVrms, 8mVpp

P1 : 0.5mVrms, 3mVpp
P2 : 0.5mVrms, 8mVpp

P1 : 0.5mVrms, 4mVpp
P2 : 0.5mVrms, 8mVpp

Normal Mode Current

1mArms

1mArms

1mArms

Resolution

Program

1mV/1mA

1mV/1mA

10mV/1mA

Readback

1mV/1mA

1mV/1mA

10mV/1mA

Meter

1mV/1mA

1mV/1mA

10mV/1mA

Voltage Programming Speed

Up - Full Load
      No Load

12msec
12msec

12msec
12msec

16msec
16msec

Down - Full Load
          No Load

15msec
110msec

15msec
110msec

20msec
250msec

Transient Response

Less than 50us for output recover to within 15mV following a change in current output from full load to half load

Command Processing Time

50msec < 100msec

»çÀ̹ö°ßÀû´ã±â

K3003D

K3005D

K6003D



    •     Bench-top and 19-inch standard rack mountable
    •     Self-compensation by monitoring output and display
    •     CV/CC mode automatic crossover by setup limit
    •     Storable up to 10 settings at each output port
    •     Power fail feature to recall the latest setting value
    •     DUT protection by OVP & OCP
    •     Rear output enable
    •     Track function which interlocks P2

Model

AK3003D

AK3005D

AK6003D

Max. Ouput power

90W x 2 / 180W

150W x 2 / 300W

180W x 2 / 360W

DC Output

Voltage

30V x 2

30V x 2

60V x 2

Current

3A x 2

5A x 2

3A x 2

Programming Accuracy     ±(% of output + offset)

Voltage

P1 : 0.03%+15mV
P2 : 0.10%+25mV

P1 : 0.03%+15mV
P2 : 0.10%+25mV

P1 : 0.05%+20mV
P2 : 0.10%+25mV

Current

P1 : 0.1%+5mV
P2 : 0.1%+10mV

P1 : 0.1%+5mV
P2 : 0.1%+10mV

P1 : 0.1%+5mV
P2 : 0.1%+10mV

Readback Accuracy     ±(% of output + offset)

Voltage

P1 : 0.03%+10mV
P2 : 0.10%+20mV

P1 : 0.03%+10mV
P2 : 0.10%+20mV

P1 : 0.05%+15mV
P2 : 0.10%+20mV

Current

P1 : 0.1%+3mV
P2 : 0.1%+7mV

P1 : 0.1%+3mV
P2 : 0.1%+7mV

P1 : 0.1%+3mV
P2 : 0.1%+7mV

Load Regulation     ±(% of output + offset)

Voltage

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

Line Regulation   ±(% of output + offset)

Voltage

0.01%+2mV

0.01%+2mV

0.01%+2mV

Current

0.01%+1mA

0.01%+1mA

0.01%+1mA

Ripple & Noise   (20Hz to 20MHz)

Normal Mode Voltage

P1 : 0.5mVrms, 3mVpp
P2 : 0.5mVrms, 8mVpp

P1 : 0.5mVrms, 3mVpp
P2 : 0.5mVrms, 8mVpp

P1 : 0.5mVrms, 4mVpp
P2 : 0.5mVrms, 8mVpp

Normal Mode Current

1mArms

1mArms

1mArms

Resolution

Program

1mV/1mA

1mV/1mA

10mV/1mA

Meter

1mV/1mA

1mV/1mA

10mV/1mA

Voltage Programming Speed

Up - Full Load
      No Load

12msec
12msec

12msec
12msec

16msec
16msec

Down - Full Load
          No Load

15msec
110msec

15msec
110msec

20msec
250msec

Transient Response

Less than 50us for output recover to within 15mV following a change in current output from full load to half load

»çÀ̹ö°ßÀû´ã±â

AK3003D

AK3005D

AK6003D



  À̸§
  ¿¬¶ôó
  E-mail
  Áö¿ª  ¿¹) °æ±âµµ ¼º³²
  ¹®Àdz»¿ë